Mike Page
Mike Page
  • Видео 101
  • Просмотров 4 183 159
Are most circuit breakers now obsolete? - Emergency Amendment 3 update to BS7671
Yo! In todays video we are talking about the Amendment 3 update to BS7671, Bi-Directional Circuit protection and what I've been up to!
If you enjoy electrical content please subscribe to the channel and checkout my links below 👇
M Y W E B S I T E ⚡
residualcurrent.com/
M Y L O A D O U T 🛠️
residualcurrent.com/pages/loadout
B I G B O O T S D I S C O U N T 🥾
bigboots.co.uk/?ref=4s3760y77o - Use code RESIDUAL
U N I L I T E D I S C O U N T 🔦
unilite.co.uk/?ref=RESIDUAL - Use code RESIDUAL
J O I N T H E C H A N N E L 🤝
ruclips.net/channel/UC-ME2vJxFANePC6e297Icwwjoin
I N S T A G R A M 📷
residualcurrent
T I K T O K ♪
vm.tiktok.com/ZM86U2jjG/
The works carried out in the video and the opinions sha...
Просмотров: 15 105

Видео

Electrical Sub-Main Installation in a Commercial Building
Просмотров 18 тыс.2 месяца назад
Yo! In todays video me and the boys are pulling a electrical cable through a commercial building, If you enjoy electrical content please subscribe to the channel and checkout my links below 👇 M Y W E B S I T E ⚡ residualcurrent.com/ M Y L O A D O U T 🛠️ residualcurrent.com/pages/loadout B I G B O O T S D I S C O U N T 🥾 bigboots.co.uk/?ref=4s3760y77o - Use code RESIDUAL U N I L I T E D I S C O ...
Installing 3 Phase RCBO's for the First Time!
Просмотров 16 тыс.3 месяца назад
Yo! In this video I'm installing3 Phase RCBO's for the first time! In my 10 years I've never even seen one of these, and while i have provided additional protection to many 3 phase circuits, its never been via an all in one - board mounted device. If you enjoy electrical content please subscribe to the channel and checkout my links below 👇 M Y W E B S I T E ⚡ residualcurrent.com/ M Y L O A D O ...
Connecting my iphone to a 1600A Air Circuit Breaker
Просмотров 6 тыс.3 месяца назад
Yo! In this video I'm connecting my phone to a 1600A Air Circuit Breaker to access the built in power quality analyzer and other cool tech! If you enjoy electrical content please subscribe to the channel and checkout my links below 👇 T A D O F O R P R O F E S S I O N A L S 🔥 www.tado.com/all-en/tado-for-professionals? M Y W E B S I T E ⚡ residualcurrent.com/ M Y L O A D O U T 🛠️ residualcurrent...
INSANE Domestic Consumer Unit Install Part 2 - Second Fix
Просмотров 18 тыс.3 месяца назад
Yo! In this video we are installing an INSANE triple stack Schneider Easy9 Multirow consumer unit! Stay Tuned for part 3! If you enjoy electrical content please subscribe to the channel and checkout my links below 👇 T A D O F O R P R O F E S S I O N A L S 🔥 www.tado.com/all-en/tado-for-professionals? M Y W E B S I T E ⚡ residualcurrent.com/ M Y L O A D O U T 🛠️ residualcurrent.com/pages/loadout...
INSANE Domestic Consumer Unit Install Part 1 - Prep Work
Просмотров 27 тыс.3 месяца назад
Yo! In this video we are installing an INSANE triple stack Schneider Easy9 Multirow consumer unit! Stay Tuned for part 2! If you enjoy electrical content please subscribe to the channel and checkout my links below 👇 M Y W E B S I T E ⚡ residualcurrent.com/ M Y L O A D O U T 🛠️ residualcurrent.com/pages/loadout B I G B O O T S D I S C O U N T 🥾 bigboots.co.uk/?ref=4s3760y77o - Use code RESIDUAL ...
Horrendous EV Charger Install - What were they thinking?
Просмотров 17 тыс.4 месяца назад
Yo! Welcome back, in this video we are looking at a horrendous EV Charger Install, going through the issues and wondering what the electricians who did it were thinking! If you enjoy electrical content please subscribe to the channel and checkout my links below 👇 M Y W E B S I T E ⚡ residualcurrent.com/ M Y L O A D O U T 🛠️ residualcurrent.com/pages/loadout B I G B O O T S D I S C O U N T 🥾 big...
Commercial Electrical Fault Finding
Просмотров 18 тыс.4 месяца назад
Commercial Electrical Fault Finding
Electric vehicle charger testing with the new KEWEVA
Просмотров 4,3 тыс.4 месяца назад
Electric vehicle charger testing with the new KEWEVA
My Goals as an Electrician in 2024
Просмотров 6 тыс.4 месяца назад
My Goals as an Electrician in 2024
How to BREAK a 250A Circuit Breaker
Просмотров 11 тыс.4 месяца назад
How to BREAK a 250A Circuit Breaker
Re-wiring a BURNT OUT building
Просмотров 16 тыс.5 месяцев назад
Re-wiring a BURNT OUT building
Tado Smart Thermostat V3+ Installation
Просмотров 9 тыс.5 месяцев назад
Tado Smart Thermostat V3 Installation
Re-wiring MELTED Electrical Supplies
Просмотров 17 тыс.5 месяцев назад
Re-wiring MELTED Electrical Supplies
I’m Back.
Просмотров 9 тыс.5 месяцев назад
I’m Back.
Calibrating your Electrical Tester
Просмотров 3,9 тыс.7 месяцев назад
Calibrating your Electrical Tester
Earth Electrode Testing - Three Lead Stake Method
Просмотров 9 тыс.8 месяцев назад
Earth Electrode Testing - Three Lead Stake Method
Electrical Earth Rod Installation - New TT Supply
Просмотров 39 тыс.10 месяцев назад
Electrical Earth Rod Installation - New TT Supply
Connecting an Electricity Meter to a LIVE Service Cut-out
Просмотров 78 тыс.10 месяцев назад
Connecting an Electricity Meter to a LIVE Service Cut-out
Connecting up a Three Phase Distribution Board
Просмотров 10 тыс.10 месяцев назад
Connecting up a Three Phase Distribution Board
3 Phase Surge Protection Installation
Просмотров 18 тыс.10 месяцев назад
3 Phase Surge Protection Installation
Carpark Street Lighting Fault Find
Просмотров 15 тыс.11 месяцев назад
Carpark Street Lighting Fault Find
Commercial Distribution Board Second Fix
Просмотров 11 тыс.11 месяцев назад
Commercial Distribution Board Second Fix
Earth Fault Loop Impedance Testing - ZS
Просмотров 12 тыс.11 месяцев назад
Earth Fault Loop Impedance Testing - ZS
Commercial Distribution Board Installation
Просмотров 21 тыс.Год назад
Commercial Distribution Board Installation
Commercial EV Charger Testing
Просмотров 23 тыс.Год назад
Commercial EV Charger Testing
Low Voltage Cable Spiking
Просмотров 56 тыс.Год назад
Low Voltage Cable Spiking
On-Site Electrical Validations
Просмотров 13 тыс.Год назад
On-Site Electrical Validations
Schneider Consumer Unit Installation
Просмотров 17 тыс.Год назад
Schneider Consumer Unit Installation
Temporary Building Site Electrical Supplies
Просмотров 17 тыс.Год назад
Temporary Building Site Electrical Supplies

Комментарии

  • @jackdean6558
    @jackdean6558 Час назад

    Proteus ones take up less space

  • @leem270
    @leem270 2 часа назад

    I recently bought the amendment 2 brown books to do my 18th edition. Will these be no good now?

  • @M0PAX
    @M0PAX 3 часа назад

    Good luck on the new stuff. With this new amendment I can now see myenergi telling you on a warranty claim “oh I can see a bidirectional device not fitted we cant approve the warranty”

  • @VladimirLadev
    @VladimirLadev 22 часа назад

    Great show and tell thank you.

  • @TechOne7671
    @TechOne7671 День назад

    Get yourself a fuse, they don’t care.

  • @dansheppard2965
    @dansheppard2965 День назад

    I've always thought it dodgy when I saw installs have things like solar on the load side of an RCBO. I couldn't quite say what was wrong, from what I know about the way RCBOs are designed (not an expert), but it's always seemed a bit howyadoin.

  • @alanoshea3472
    @alanoshea3472 День назад

    Top man is back

  • @martinburgess2322
    @martinburgess2322 День назад

    Good to see you Mike. Hope all is well bud ⚡👍😎

  • @MrLeecavturbo
    @MrLeecavturbo 2 дня назад

    How do you explain that AC is alternating for old devices so they won’t work for a fault that is in the reverse phase ! And since inverters only supply the busbar sub circuits have single direction power flow ( ignoring AC ) and have their appropriate protection as required. This is as daft as double insulated core SWA’s 🤣

  • @johnlansing2902
    @johnlansing2902 2 дня назад

    Thank you for your time .

  • @connor4891
    @connor4891 2 дня назад

    No wire strippers

  • @effervescence5664
    @effervescence5664 2 дня назад

    I have already been C2'ing installations during EICR's because RCD's aren't bidirectional when protecting solar/ wind power which have burnt out on the solenoid. Initially it was because if the test button doesn't work = C2 but after Mark Allisons video last year I've been amending my comments to list "needs a bidirectional rcd". Biggest issue being that not every manufacturer is making it easy to find out and not every technical helpline has someone at the end of it that knows if their product is or isn't. Hats off to the chap on Efixx comments the other day that told me to phone M2, their technical helpline is one of the best for knowledge on their products I've had to deal with. Sadly the latest EICR with an RCD issue on solar I C2'd has gone radio silent, possibly due to the amendment dropping a couple days later and realising they potentially have thousands of installs nation wide which they're now liable for the design and rectification of.

  • @nathanbaldini8622
    @nathanbaldini8622 2 дня назад

    Mike Page - Legend 💪

  • @taibrook5426
    @taibrook5426 2 дня назад

    Look at you Mr black hat. Yes bro 💪

  • @mfr58
    @mfr58 2 дня назад

    I asked engineers about this way back at the start of solar and everyone seemed to think it wasn't a problem. How come the mighty IET only now have got their arse in gear? Are they going to pay to put all the installs right?

    • @guffermeister
      @guffermeister 2 дня назад

      Because the IET is usually a decade behind the real world - by their own admission. With solar on it's own it probably isn't as much, but with battery storage now becoing popular and island mode now appearing it problably is starting to be more of an issue. We've had this with the first couple of goes at AFDD's with the stupid lookup likelyhood of lightning which thankfully got quickly abandoned, to the then EV charing points about having PEN protection and all that

    • @MrLeecavturbo
      @MrLeecavturbo 2 дня назад

      If they are saying they don’t function they’ve also just made every single devices todate ineffective since AC flows in both directions by definition 🤣🤣👍

  • @bigissue9179
    @bigissue9179 2 дня назад

    EVEN A REWIRABLE FUSE IS BIDIRECTIONAL LOAD OF BOLLOCKS

  • @MichaelAnderson436
    @MichaelAnderson436 2 дня назад

    Glad you're back boss!

  • @walseee
    @walseee 2 дня назад

    So if you don’t use a Bi-directional device on solar installs for example it can damage the MCB, so the manufacturers have put into their warranty’s that if they break because of this it’s not their problem?

  • @laujovo5368
    @laujovo5368 2 дня назад

    The unidirectionality of "usual" devices only comes from the fact that most RCBO etc. in the UK are based on a microcontroller, right? Reason for my question is I'm based in Germany and we are told that it absolutely doesn'T matter how you connect RCDs, RCBOs etc. and they do not have any markings on them whatsoever, whether one terminal is the load side and one the grid side of it (they are solely based on the electro-magnetic and bimetallic principle). Would love to hear your comment on it! :) Oh and by the way get well! Wish you the best!

    • @wiedapp
      @wiedapp 2 дня назад

      As long as you're using a RCD type A that's correct. With type B RCD it's a bit different, because of the electronics inside.

    • @circuitbreaker1434
      @circuitbreaker1434 День назад

      ​@@wiedappeven most of the type b work in both directions 😅

    • @wiedapp
      @wiedapp День назад

      @@circuitbreaker1434 Yes, they do. However: The internal PSU doesn't like being repeatedly cut off from power, after being constantly connected to it for months. Therefore it is technically better to connect them in the right way. A PSU will always be a PSU, even inside an RCD.

  • @electrician247
    @electrician247 2 дня назад

    Awesome stuff Mike

  • @awsometomable
    @awsometomable 3 дня назад

    Good to see you bud!

  • @sergiofernandez3725
    @sergiofernandez3725 3 дня назад

    Good to see you back on RUclips Mike. No need to apologise for lack of content, your true fans will understand.

  • @Richardincancale
    @Richardincancale 3 дня назад

    Bi-directional RCBOs sounds like a good idea on circuits with microgeneration but… please correct me if I’m wrong …aren’t most RCBOs inherently bi-directional? They typically rely on a bimetallic strip for light overload, and magnetic coil for big overloads, plus a toroidal transformer carrying line and neutral with a detection coil to trip in case of an imbalance. I don’t see why any of these components would be directional? Is it really just a labelling issue?

    • @residualcurrent
      @residualcurrent 3 дня назад

      I believe uni-directional RCBOs if powered from the load side have the potential for the solenoid and RCD logic board to burn out as they remain energised, proteus did a good video explaining it, the bi-directional RCBO’s have an additional contact internally. I believe that this same level of protection can be achieved with and MCB and RCCB both of which have generally been bi-directional for years, do check specs though, verso have a little PV board that does exactly this 🤝🏼

    • @GraemeMcKeague
      @GraemeMcKeague 3 дня назад

      @@residualcurrent But if the microgeneration (inverter) detects no grid, It shuts down almost instantly and doesn't generate any power, to "back feed" a RCBO. Having a Bisdirectional would leave an extra level of safety especially if its just a drop in replacement rcbo, on any future installs.

    • @retrozmachine1189
      @retrozmachine1189 2 дня назад

      I'm no expert in these matters, not by any means. I'm just an older bloke that had little to do with RCDs having worked in the '80s. It's about 2 things from what I can tell. The manual test button being held in for an extended period, which is the main concern, and devices that do not switch the neutral. The test button part is obvious, but the neutral part may not be. From what I've read about the ICs used etc no RCD latches the earth fault state - ie once the imbalance through the CT ceases the coil current is reduced back to pre-trip condition (there is always minor current through the trip coil with electronic types). This is backed up by actually experimenting with several 'directional' RCD/RCBOs available in Australia, the trip is repeatedly fired with supply on the wrong side and you can hear it but once the imbalance stops so does the firing. Of course, there may well be an RCD out there that does latch the condition and does place high current through the coil essentially until it burns out. Imagine you have a non-neutral switching electronic RCD, a N/E fault downstream of the RCD, and supply on the wrong side which will keep the electronics working post trip. The RCD will trip but imbalance potentially remains present due to the N/E fault, so the coil is left with high current indefinitely. A magnetic RCD would have a similar issue with N/E faults since the coil is powered by the CT directly but I'm not sure if it would cause a problem since it's only trying to disrupt the hold-in magnet rather than whacking the heck out of the trip mechanism like electronics do. Ensuring the use of neutral switching RCDs will address N/E faults, switching the test circuit addresses excessively long presses of the test button. Happy for anyone to make any comments about the above to explain why it may be incorrect.

    • @leexgx
      @leexgx 2 дня назад

      @@GraemeMcKeague the issue is when a solar panel system is wired into a consumer unit, They typically wire the load side of the RCBO from the solar inverter so are always receiving load on the load side of the circuit breaker (it’s always back feeding when inverter is making power) so it might destroy the RCBO circuitry if it’s not bi-directional Same would happen if using ac couple battery storage system when it is discharging the power to the house it will be backfeeding via the load side of the RCBO

    • @electrician247
      @electrician247 2 дня назад

      @@GraemeMcKeague In normal operation the PV is constantly back feeding the RCBO, as Mike has answered that can potentially damage the circuitry inside the RCBO. Especially when they operate under faults or the test button is pressed. With Hybrid inverters and battery storage the flow of energy is consistently in both directions so its essential we start to use true bidirectional devices.

  • @dukeycarrow
    @dukeycarrow 3 дня назад

    RETURN OF THE MAC 🎶 good to see you and your knowledge back lad 👌

    • @residualcurrent
      @residualcurrent 3 дня назад

      Haha very kind! It’s good to be back 🤝🏼

  • @Jake_Baker_Electrician1997
    @Jake_Baker_Electrician1997 3 дня назад

    Yes Mike! Been waiting for one of your videos! Hope all is well dude 👍🏼

  • @residualcurrent
    @residualcurrent 3 дня назад

    Comment on the BS7671:2018 A3 DPC - electrical.theiet.org/bs-7671/updates-to-18th-edition/ BEAMA Technical Bulletin - www.beama.org.uk/resourceLibrary/beama-technical-bulletin---connection-of-unidirectional-and-bidirectional-protective-devices.html

  • @Cpt_Dave
    @Cpt_Dave 6 дней назад

    The double edged Knipex one has 2 different functions. Upper blade is for cutting isolation, making the cable smaller. Lower one is for the actual cut.

  • @ilovetitanium4136
    @ilovetitanium4136 9 дней назад

    Not sure a hex key in the Knipex shears is the best way. Hex bit in a ratchet might be better and won't ruin the cutters.

  • @SpikesMavic
    @SpikesMavic 10 дней назад

    But if the test Spikes are into dry ground, what will that measure ?

  • @andrewwhite3793
    @andrewwhite3793 14 дней назад

    Is the time clock a normal one or an Astro clock ? reason I ask I had a job where the customer spent daft money getting the main contractor out 5-6 times a year to suit the seasons and summer/winter times. I fitted an Astor clock that shadows the area you are in sunset and sunrise time plus it automatically changes the summer winter times

  • @retrun813
    @retrun813 14 дней назад

    Hey Mike its been nearly 6 months. Are you planning any video of reviewing this system over time? currently i am on a buy and cannot decide between these and Meross one. Take care!

  • @sajeevipiumika4033
    @sajeevipiumika4033 14 дней назад

    Is this for TT system?

  • @ceangasrevenge
    @ceangasrevenge 14 дней назад

    Youse guys don't do the tighten loosen wiggle tighten torque method ?

  • @dorianwylie9000
    @dorianwylie9000 14 дней назад

    I find it handy to have one not only for bonding but to go round all the metal faceplates if any and touch off them to see if the earth is continuous

  • @circuitbreaker1434
    @circuitbreaker1434 15 дней назад

    you may want to look into the DS203NC series from ABB 😅

  • @samuelanderson1338
    @samuelanderson1338 19 дней назад

    That’s a Del Roy type job

  • @chrismason3341
    @chrismason3341 25 дней назад

    Dno or supplier still not been out to reseal?

  • @chrismason3341
    @chrismason3341 26 дней назад

    The inspection cover is pointless as the dno have only left you with a tt as its a temporary supply and will be redundant when the permanent supply is re installed.Secondly you dont want to be kneeling on that joint, your likely to over stress the old lead causing premature failure of the joint or cause a flash over

  • @atharsabir5043
    @atharsabir5043 26 дней назад

    During connection there is 110 v appearing in earth line

  • @jamesgee474
    @jamesgee474 27 дней назад

    Always connect neutral 1st when making it off into live cutout

  • @chas3997
    @chas3997 Месяц назад

    2 errors here don’t run the earth in front of tails ( also don’t touch tails) 1667 is the maximum for additional protection. But 100ma time delayed ADS is a maximum of 500ohms. You may have to cover both ADS and Additional protection depending on safety assessment.

  • @jackwolf121
    @jackwolf121 Месяц назад

    Interesting info from Google “A bubble level has a measuring accuracy of 0.5 mm/meter in both normal and reverse positions. As we have seen, a digital level has an accuracy of +/- 0.05 degrees from 0-90 degrees and +/- 0.2 degrees from 1-89 degrees. So there is almost no difference between them, less than would ever be noticeable by the human eye”

  • @seanjay886
    @seanjay886 Месяц назад

    That previously intro was absolute 🔥I loved the drama and suspense it created. Not only is your sparkie game on point. Your production and editing is mint mate. 10/10 would recommend

  • @tonywatson1412
    @tonywatson1412 Месяц назад

    At the end , your neutrals and earths , connect them together. but WE know what you mean....!!!

  • @tonywatson1412
    @tonywatson1412 Месяц назад

    See so many electricans with gloves on...is there really any need for it...? wouldnt like the loss of feel

  • @iancoles1349
    @iancoles1349 Месяц назад

    U will damage the edges on u brand new knipex shears doin that Deff a code v